Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede2.pucgoias.edu.br:8080/handle/tede/4459
Tipo do documento: Dissertação
Título: Validação do software HRVCAM para avaliação da frequência cardíaca e da variabilidade da frequência cardíaca
Título(s) alternativo(s): Validation of HRVCAM software to assess heart rate and heart rate variability
Autor: Martins, Patrícia Cândida de Matos Lima 
Primeiro orientador: Vitorino, Priscila Valverde de Oliveira
Primeiro coorientador: Barbosa, Talles Marcelo Gonçalves de Andrade
Primeiro membro da banca: Ramos, Gabrielly Craveiro
Segundo membro da banca: Barroso, Weimar Kunz Sebba
Resumo: Estudo de validação, realizado com adultos saudáveis em uma instituição de ensino superior do Brasil, com o objetivo de validar o software HRVCam para a medição da frequência cardíaca (FC) e da variabilidade da frequência cardíaca (VFC). Foram coletados dados sociodemográficos e de saúde e avaliadas a FC e a VFC por meio de uma webcam e do monitor de FC Polar‚ S810i, que foi o método escolhido para a comparação. Destes instrumentos, foram avaliadas e colhidas as seguintes variáveis: frequência cardíaca (FC), intervalo R-R (iR-R), desvio padrão de todos os intervalos R-R normais gravados em um intervalo de tempo, expresso em ms (SDNN), raiz quadrada da média do quadrado das diferenças entre intervalos R-R normais adjacentes, em um intervalo de tempo, expresso em ms (rMSSD), alta frequência (AF), baixa frequência (BF) e razão entre baixa frequência e alta frequência (BF/AF). Aplicou-se o Teste de Shapiro-Wilk para testar a normalidade dos dados; coeficiente de correlação de Pearson (r) para análise das possíveis correlações entre os dois instrumentos; para analisar a concordância entre os métodos utilizou-se o tamanho do efeito calculado com base em modelo linear generalizado e os gráficos de BlandAltman. O nível de significância para todas as análises foi de p < 0,05. Foram avaliados 102 participantes, sendo 52% do sexo masculino; 83,3% encontravam-se na faixa etária de 18 a 29,9 anos e 84,3% viviam sem companheiro. Houve boa concordância e moderada a forte correlação para todas as variáveis analisadas. Os vieses foram baixos, exceto para as medidas de BF/AF e a diferença entre as medidas foi de pequena a moderada. Este trabalho propôs uma metodologia de validação para um instrumento de medida e apresentou resultados consistentes que corroboram para a utilização do HRVCam como medidor de FC e da VFC
Abstract: Validation study performed with healthy adults at a Brazilian higher education institution to validate HRVCam software for heart rate (HR) and heart rate variability (HRV) measurements. Sociodemographic and health data were collected and the HR and HRV were evaluated by means of a webcam and the FC Polar‚ S810i monitor, which was the method chosen for the comparison. The following variables were evaluated and collected: heart rate (HR), RR mean (iR-R), standard deviation of all normal RR intervals recorded in a time interval, expressed in ms (SDNN), square root of (rMSSD), high frequency (AF), low frequency (BF) and the ratio between low frequency and high frequency (BF / AF). The Shapiro-Wilk test was applied to test the normality of the data. The Shapiro-Wilk Test was applied to test the normality of the data; Pearson correlation coefficient (r) for analysis of possible correlations between the two instruments; to analyze the agreement between the methods was used the effect size calculated based on generalized linear model and the Bland-Altman plots. The significance level established for all analyzes was p <0.05. A total of 102 participants were evaluated, 52% of them male; 83,3% were in the age range of 18 to 29,9 years and 84,3% lived without partners. There was good agreement and significant correlations between the methods for all variables: HR (r= 0,99), RRmean (r= 0,99), SDNN (r= 0,96), RMSSD (r= 0,93), HF (r= 0,61), LF (r= 0,59) e LF/HF (r= 0,84). Bias ranged from -7.74 to 0.55 and was higher for LF/HF measurements. The effect size ranged from 0,0008 to 0,282, reflected in small differences for all measurements, except for RMSSD; LF and LF/HF in which the differences were moderate. This work proposed a validation methodology for a measurement instrument and presented consistent results that corroborate the use of HRVCam as a HR and HRV meter
Palavras-chave: Estudos de Validação; Frequência Cardíaca; Fotopletismografia
Validation Studies; Heart Rate; Photoplethysmography
Área(s) do CNPq: CNPQ::CIENCIAS::CIÊNCIAS DA SAÚDE
Idioma: por
País: Brasil
Instituição: Pontifícia Universidade Católica de Goiás
Sigla da instituição: PUC Goiás
Departamento: Escola de Ciências Sociais e da Saúde
Programa: Programa de Pós-Graduação STRICTO SENSU em Atenção à Saúde
Citação: Martins, Patrícia Cândida de Matos Lima. Validação do software HRVCAM para avaliação da frequência cardíaca e da variabilidade da frequência cardíaca. 2019. 84 f. Dissertação (Mestrado em Atenção à Saúde) -- Escola de Ciências Sociais e da Saúde, Pontifícia Universidade Católica de Goiás, Goiânia, 2019.
Tipo de acesso: Acesso Restrito
URI: http://tede2.pucgoias.edu.br:8080/handle/tede/4459
Data de defesa: 11-Mar-2019
Aparece nas coleções:Mestrado em Atenção à Saúde
Mestrado em Atenção à Saúde

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Patrícia Cândida de Matos Lima Martins.pdf2,91 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar    Solictar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.