Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede2.pucgoias.edu.br:8080/handle/tede/5032
Tipo do documento: Dissertação
Título: Georreferenciamento e monitoramento de temperatura em tempo real durante transporte de materiais biológicos humanos
Título(s) alternativo(s): Georeferencing and real-time temperature monitoring during transport of human biological materials
Autor: Diniz, Rogério Martins 
Primeiro orientador: Pfrimer, Irmtraut Araci Hoffmann
Primeiro membro da banca: Junqueira, Isabela Cinquini
Segundo membro da banca: Borges, Leonardo Luiz
Resumo: Durante o transporte de material biológico humano devem-se ser seguidas diretrizes regulamentas para garantir que a amostra chegue integra e conservada até o local de processamento. Amostras biológicas deterioradas ao serem analisadas, podem gerar resultados falsos negativos ou positivos, trazendo consequências indesejáveis para o paciente. Este estudo teve como objetivo monitorar as condições de transporte de amostras biológicas, utilizando novas tecnologias e embalagens de transportes elétricas que eliminam elementos refrigerados como gelos artificiais. Foi avaliado e comparado a temperatura das amostras biológicas transportadas (em ºC), durante 06 dias consecutivos, utilizando duas caixas de transporte de material biológico diferentes: (1) caixa térmica passiva refrigerada com gelos artificiais e (2) caixa elétrica ativa com bateria de Lítio de longa duração, refrigeradas por sistema composto por circuito fechado que utiliza compressor e serpentina. Ao todo foram percorridos 2.247,1 km e coletadas 10.606 amostras biológicas em 11 laboratórios de análises clínicas diferentes. Durante todo o estudo foram utilizados 54 gelos artificiais para refrigerar as amostras biológicas transportadas na caixa passiva, o monitoramento da temperatura foi realizado através de sensores instalados nas duas caixas, que permitem o rastreamento e monitoramento de temperatura on-line em tempo real. Em todos os dias analisados, a caixa ativa se mostrou mais eficiente em relação a caixa passiva, mantendo a temperatura média, durante o trajeto até a entrega final dentro das exigências estabelecidas (2 a 8°C).. A variação da temperatura do ambiente não interferiu diretamente na temperatura interna em nenhuma das embalagens utilizadas no estudo para este tipo de transporte. Estima-se que em 12 meses, 2.160 gelos artificiais deixariam de ser utilizados somente para a rota do transporte de material biológico, mostrando que o investimento em novas embalagens deve ser analisado e pode ser viável financeiramente
Abstract: During the transport of human biological material, regulatory guidelines must be followed to ensure that the sample arrives intact and preserved at the processing site. Biological samples that deteriorate when analyzed can generate false negative or positive results, bringing undesirable consequences for the patient. This study aimed to demonstrate the improvement in the conditions for transporting biological samples, using new technologies and electrical transport packages that eliminate refrigerated elements such as artificial ice. The temperature of the transported biological samples (in ºC) was evaluated and compared during 06 consecutive days, using two different transport boxes for biological material: (1) passive thermal box refrigerated with artificial ice and (2) active electrical box with battery Long-lasting lithium, refrigerated by a system composed of a closed circuit that uses a compressor, coil and eliminates the need for artificial ice. In all, 2,247.1 km were traveled and 10,606 biological samples were collected in 11 different clinical analysis laboratories. Throughout the study, 54 artificial ices were used to refrigerate the biological samples transported in the passive box, temperature monitoring was performed through sensors installed in both boxes, which allow tracking and monitoring of temperature online in real time. On all the days analyzed, the active electrical box proved to be more efficient than the passive box, maintaining the average temperature, with standard deviation, during the journey to the final delivery within the established requirements (2 to 8°C). variation in ambient temperature did not directly interfere with the internal temperature in any of the packages used in the study for this type of transport. It is estimated that in 12 months, 2,160 artificial ices would no longer be used only for the route of transporting biological material, showing that investment in new packaging should be analyzed and may be financially viable
Palavras-chave: Materiais biocompatíveis
Monitoramento biológico
Transporte de contaminantes
Biocompatible materials
Biological monitoring
Transport of contaminants
Área(s) do CNPq: Ciências da Saúde
Idioma: por
País: Brasil
Instituição: Pontifícia Universidade Católica de Goiás
Sigla da instituição: PUC Goiás
Departamento: Escola de Ciências Médicas e da Vida
Programa: Programa de Pós-Graduação STRICTO SENSU em Ciências Ambientais e Saúde
Citação: DINIZ, Rogério Martins. Georreferenciamento e monitoramento de temperatura em tempo real durante transporte de materiais biológicos humanos. 2023. 43 f. Dissertação (Mestrado em Ciências Ambientais e Saúde) -- Escola de Ciências Médicas e da Vida, Pontifícia Universidade Católica de Goiás, Goiânia, 2023.
Tipo de acesso: Acesso Aberto
URI: http://tede2.pucgoias.edu.br:8080/handle/tede/5032
Data de defesa: 30-Jun-2023
Aparece nas coleções:Mestrado em Ciências Ambientais e Saúde

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Rogério Martins Diniz.pdf.crdownloadTexto completo707,75 kBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.